Celdar® Technology

Celdar® Technology

Cod and smells removal in vinegar wastewater

Location: ITALY

PRODUCED WASTEWATER: 15 cubic meter/hour

Typical problems in wastewater: COD of poorly degradable substances and smell

TREATMENT PRINCIPLES AND AIMS

The customer asked us to evaluate the ELECTROCOAGULATION SYSTEM for the COD and smells removal to be able to drain the treated water into the sewer system.

Another option required was the  possibility of water recycling with the least amount of consumption possible.

This option is possible using an ELECTROCOAGULATION PLANT since no chemicals are used and therefore the physical and chemical characteristics of the water to be treated have little variation compared to the treated water.

 

The obtained results and working conditions are below:

Type of electrodes: CELDAR

Trial condition: 7 - 14 Volt / 35 - 70 Ampere

Temperature increasing (Joule effect): Negligible

Foam: considerable presence and in compact form

(look at the first graph)

replicas relojes

The results obtained are satisfactory for carrying out a pre-treatment because the removal of COD deriving from poorly biodegradable substances was excellent and especially the problem of bad odour was solved.

No chemical-physical treatment had succeeded in obtaining a reduction of these parameters; therefore, the customer accepted  the installation of an Electrocoagulation